Continent
Europe (57)
Asia (31)
Africa (2)
Americas (3)
Country
Azerbaijan (1)
Bulgaria (1)
China (1)
Germany (45)
India (2)
Canada (1)
Qatar (6)
Kuwait (3)
Lebanon (1)
Mauritius (1)
Panama (1)
Russia (7)
Saudi Arabia (4)
Czechia (1)
Turkey (7)
Hungary (1)
United Arab Emirates (6)
United States of America (1)
Egypt (1)
United Kingdom (2)
Building Function
Education (4)
Office (54)
Health (4)
Shopping (23)
High-Rise (22)
Hotel (14)
Culture (9)
Mixed-Use (29)
Sport (1)
Transport (8)
Residential (14)
Key Feature
Unitized Curtain Wall (46)
Stick System (54)
Double Skin (11)
Glass Fin (5)
Rain Screen (32)
Exhaust Air (3)
Roof (21)
Energy (8)
Security (3)
Sun Protection (34)
Geometry (16)
Innovation (8)
Main Material
Ceramic (8)
Composite (12)
Concrete (5)
Glass (71)
Metal (53)
Membrane (2)
Stone (18)
Wood (3)
Other (5)
Height
Up to 50m (49)
Up to 100m (19)
Up to 200m (15)
Up to 300m (8)
Higher (2)
Our Services
Research & Development (10)
Consultancy (80)
Engineering (15)
Specials (44)
Continuous Support (4)
Refurbishment (12)
Status
Competition (0)
In Planning (4)
Under Construction (3)
Completed (91)
Not Built (0)

Tour Total, Berlin


Map 

Client

omniCon, Berlin


Owner / Developer

Vivico Berlin, Europaplatz 01 GmbH & Co. KG


Architect

Barkow Leibinger Architekten


Building Function

Office


Status

Completed 09/2012


Facade Scale

approx. 6.500 m²


Height

approx. 70 m


Technical Features
  • Precast concrete elements
  • Punch windows
  • External sunshade, wind-stable
  • DGNB-silver certified

View location in Google Maps

We provided

Consultancy

Sound facade decisions start with a clear understanding of the project’s starting point.

  • Priedemann organises the available project information, design intent, use, and facade-related technical and external requirements.
  • Together with the project participants, objectives, priorities, constraints and unresolved questions are made visible.
  • This creates a reliable basis for the next design steps and for decisions before the facade concept is developed in greater detail.
  • Priedemann identifies and structures the project information, requirements, objectives and constraints relevant to facade planning.
  • These may include design intent, use, technical and energy-related requirements, local conditions, and quality, cost and programme objectives.
  • Unresolved questions, dependencies and competing priorities are made explicit and translated into clear decision criteria.
  • This creates a reliable basis for early facade design and subsequent planning.
  • The subjects reviewed and documented depend on the project stage and agreed scope.

Decision criteria and priorities

  • Not every facade requirement has the same priority within a project.
  • Design intent, use, technical requirements, local conditions, quality, cost and programme objectives can influence one another.
  • Establishing the project basis therefore also means structuring these requirements and making potential conflicts visible.
  • The resulting criteria provide a shared basis against which later options and decisions can be assessed consistently.

Facade design for statutory approval develops an existing facade concept for the project’s approval and coordination context.

  • Priedemann brings together available design information, technical requirements, materials, facade types and interfaces.
  • Depending on the project, fire, safety, building-physics and acoustic requirements are also considered.
  • The result is a clear facade basis for coordination with the relevant disciplines and for subsequent design.
  • Facade design for statutory approval develops the facade information needed to demonstrate relevant approval requirements.
  • Depending on the appointment, Priedemann addresses technical facade subjects, interfaces, fire and safety requirements, and the necessary design information.
  • Unresolved points are coordinated with the relevant disciplines and technical contributions are documented.
  • The scope, submission process and responsibility for the complete statutory application are agreed for the project.

Technical facade design develops an agreed facade solution into coordinated technical information for implementation.

  • Details, components, connections and interfaces are brought together with requirements for construction, materials, building physics, acoustics, fire and safety.
  • The required level of development depends on the project, procurement model and appointment.
  • This creates a consistent basis for subsequent shop, production and installation planning.
  • Technical facade design develops an agreed facade solution in sufficient detail for subsequent implementation.
  • Depending on the appointment, Priedemann develops principle details, connections, layers, components, materials and dimensions, and coordinates interfaces with adjacent construction.
  • Structural, building-physics, acoustic, fire and safety requirements are considered to the agreed design depth.
  • The result is coordinated design information that can provide a basis for shop, production and installation drawings.
  • The precise scope is defined for each project.

Facade specifications and tender documentation translate developed facade design into clear technical requirements for tendering and bid comparison.

  • Priedemann structures information on construction, materials, details, interfaces and quality criteria and brings the relevant design documents together.
  • Depending on the project, this can include technical preliminaries, specifications, quantity information or trade boundaries.
  • The scope and function of the documents depend on the procurement and responsibility model.
  • Priedemann translates the agreed facade design into technical specifications and tender documentation.
  • Requirements, quality criteria, materials, components, interfaces and required evidence are structured and described clearly.
  • Depending on the appointment, quantities, component schedules and other technical appendices may be included.
  • The documents provide a consistent technical basis for bids and the subsequent award process.
  • The scope and responsibility for the complete tender package are agreed with the client.

During technical tender evaluation, Priedemann compares submitted facade bids with the previously defined requirements and tender documents.

  • The review can cover technical content, qualification evidence, bidder alternatives, proposed systems and identifiable deviations.
  • Unresolved points are structured for tender interviews and the findings are documented clearly.
  • Price-related or commercial assessment is included only where it is expressly part of the appointment.
  • During technical tender evaluation, Priedemann compares facade bids with the defined requirements and tender documentation.
  • The review may consider technical completeness, qualifications, proposed systems and materials, bidder alternatives, and identifiable deviations or risks.
  • Findings are documented clearly and can provide technical support during tender interviews.
  • Price comparison, commercial review and the final award decision form part of the service only where expressly agreed.
Let's talk about your project