Max Dudler GmbH
Leibniz University Hannover
Max Dudler GmbH
University
Under construction
approx. 70 m
Priedemann offers comprehensive knowledge of materials, types of construction and construction methods for assessing the quality and value of the inventory with minimized depth of interference with the material.
Taking into account listed buildings, economic and design requirements such as preservation of individual details, renovation during ongoing operation, gutting with new extension, etc., we develop targeted renovation concepts for the facade on the basis of precise measurements as well as material, strength and load-bearing capacity analyses.
Sound facade decisions start with a clear understanding of the project’s starting point.
Decision criteria and priorities
Early facade design begins once the strategic objectives and principal requirements of a project are sufficiently understood for possible directions to be developed.
Facade design for statutory approval develops an existing facade concept for the project’s approval and coordination context.
Technical facade design develops an agreed facade solution into coordinated technical information for implementation.
Priedemann uses computer-based simulation where standardised calculation methods are no longer sufficient. This covers room-comfort simulation based on ISO 7730 together with heating and cooling loads, and, for complex systems, three-dimensional computational fluid dynamics (CFD) simulation, including sizing smoke-extraction openings. The aim is a reliable basis for concrete design decisions on critical rooms and systems.
Priedemann uses thermal and airflow simulations to investigate the behaviour of the facade, interior and building services under defined conditions. Input data for the building, use, climate and technical systems are translated into coordinated models. Depending on the brief, the analysis considers room temperatures, comfort, heating and cooling loads, airflow or temperature distribution.
Critical areas and the implications of possible options become visible. The findings support design decisions but do not replace measurement of the completed building in operation.
What simulation outputs can show
Simulation can provide more than a single performance value. Depending on the model, the analysis can consider room-air temperatures, thermal comfort, heating and cooling loads, airflow velocities and temperature distributions in the air or at surfaces. CFD simulation can also be used for defined smoke-extraction scenarios and to examine smoke-extraction or make-up-air openings. The important limitation is that every result applies to the assumptions and boundary conditions defined for that particular model.
Priedemann develops concepts for facade-integrated solar energy: heat, electricity, and solar cooling.
Depending on requirements, Priedemann analyzes and calculates the static requirements of e.g. profiles, glazing and fixings in 2 or 3 dimensions or as finite elements. Evidence is provided on the basis of the applicable international or national standards.